43
7-5 CHECK WEIGHING MODE
CHECK WEIGHING MODE 1 (WEIGHING MODE CALF-14 = 5)
Output Terminal Output Condition
Zero band
Gross Zero band
Hi-Hi Net > Hi-Hi limit
Hi Net > Target Weight + Hi limit
Go
Target Weight + Hi limit Net Target
Weight – Lo limit
Lo Net < Target Weight – Lo limit
Lo-Lo Net < Lo-Lo limit
When an output condition is established, a
relevant output terminal is turned on (power
continuity with output COM).
An output terminal number can be selected
with the general functions, OUTF-01 through
OUTF-08.
The setpoint signal output is turned off
unconditionally when the operation mode is
other than the normal mode.