A&D PD4000243 Manuale Utente Pagina 133

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 144
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 132
AD-4402 Page 131
Category address
:
[Function] - [Function setting] - [Option] - [slot
n
] - [OP-07]
OP-07: Option Analog Output
slot
n : slot number
Category
address
symbol
Name Descriptions
Range
and
choices
Default
07 f- 1
Out put data
1: Displayed value
2: Gross value
3: Net value
1 to 3 1
07 f- 2
Weight at 4 mA
Set the weighit value when 4 mA is
output.
-999999
to
9999999
0
07 f- 3
Weight at 20 mA
Set the weighit value when 20 mA is
output.
-999999
to
9999999
16000