CHECK WEIGHING MODE 3 (WEIGHING MODE CALF-14 = 7)
Output Terminal Output Condition
Zero band
Gross Zero band
Hi-Hi Net > Hi-Hi Limit
Hi Net > Hi Limit
Go
Hi Limit Net Lo Limit
Lo Net < Lo Limit
Lo-Lo Net < Lo-Lo Limit
When an output condition is established, a relevant
output terminal is turned on (power continuity with
output COM).
An output terminal number can be selected with the
general functions, OUTF-01 through OUTF-08.
The setpoint signal output is turned off
unconditionally when the operation mode is other
than the normal mode.